Computer Animation 2002
Accurate Simulation of Hip Joint Range of Motion
Geneva, Switzerland
June 19-June 21
ISBN: 0-7695-1594-0
MyungJin Kang, University of Geneva
Hassan Sadri, H?pitaux Universitaires de Gen?ve
Laurent Moccozet, University of Geneva
Nadia Magnenat-Thalmann, University of Geneva
Pierre Hoffmeyer, H?pitaux Universitaires de Gen?ve
This paper presents a hip joint motion simulation method using accurate hip joint center and hip range of motion. We calculate the extreme hip joint range of motion centered on the hip joint center (HJC) that is located by an automatic calculation algorithm on 3D reconstructed surface models. We make 3D bone surface models from CT (Computer Tomography) or MRI (Magnetic Resonance Imaging). The medical objective is to quantify hip kinematics in function of hip morphology. Because extreme ranges of motions are evaluated from bones only, we can estimate the motions that are restricted by bones impingements by comparing the computed values with real extreme range of motion.
Citation:
MyungJin Kang, Hassan Sadri, Laurent Moccozet, Nadia Magnenat-Thalmann, Pierre Hoffmeyer, "Accurate Simulation of Hip Joint Range of Motion," ca, pp.215, Computer Animation 2002, 2002