ABSTRACT
A fault detect mechanism is described for hardwired control logic. The mechanism takes advantage of inherent redundancy in the control logic design style which assigns a unique flip-flop to each machine state. The mechanism is capable of detecting all single stuck-at faults, as well as many multiple faults and intermittents within the control section.
INDEX TERMS
self-test, Control section, fault detection, fault diagnosis
CITATION
A. Miczo, "A Self-Test Hardwired Control Section", IEEE Transactions on Computers, vol.32, no. 7, pp. 695-696, July 1983, doi:10.1109/TC.1983.1676302