The Community for Technology Leaders
RSS Icon
Subscribe
Issue No.11 - November (1978 vol.27)
pp: 1059-1063
G.G.L. Meyer , Department of Electrical Engineering, The Johns Hopkins University
ABSTRACT
A new diagnosis algorithm for determining the existing fault situation in a symmetric multiple processor architecture is given. The algorithm assumes that there are n processors, each of which is tested by at least t other processors, and at most t of which are faulty. The existing fault situation is always diagnosed if n = 2t + 1 and, in some cases, can still be diagnosed if n < 2t + 1. The imple
INDEX TERMS
modular networks, Diagnosis algorithm, fault syndromes, microprocessor
CITATION
G.G.L. Meyer, "An Efficient Fault Diagnosis Algorithm for Symmetric Multiple Processor Architectures", IEEE Transactions on Computers, vol.27, no. 11, pp. 1059-1063, November 1978, doi:10.1109/TC.1978.1674996