| This Article | ||
| ||
| Share | ||
| Bibliographic References | ||
| Add to: | ||
| | ||
| Search | ||
| ||
Eighth International Conference on Information Visualisation (IV'04)
Imaging Panel Skew Correction and Auto-focusing in Radiotherapy Cone Beam Imaging
London, England
July 14-July 16
ISBN: 0-7695-2177-0
| ASCII Text | x | ||
| Amer Ali, Sykes Jonathan, Moore Christopher, "Imaging Panel Skew Correction and Auto-focusing in Radiotherapy Cone Beam Imaging," 2010 14th International Conference Information Visualisation, pp. 92-97, Eighth International Conference on Information Visualisation (IV'04), 2004. | |||
| BibTex | x | ||
| @article{ 10.1109/IV.2004.1320130, author = {Amer Ali and Sykes Jonathan and Moore Christopher}, title = {Imaging Panel Skew Correction and Auto-focusing in Radiotherapy Cone Beam Imaging}, journal ={2010 14th International Conference Information Visualisation}, volume = {0}, year = {2004}, issn = {1093-9547}, pages = {92-97}, doi = {http://doi.ieeecomputersociety.org/10.1109/IV.2004.1320130}, publisher = {IEEE Computer Society}, address = {Los Alamitos, CA, USA}, } | |||
| RefWorks Procite/RefMan/Endnote | x | ||
| TY - CONF JO - 2010 14th International Conference Information Visualisation TI - Imaging Panel Skew Correction and Auto-focusing in Radiotherapy Cone Beam Imaging SN - 1093-9547 SP92 EP97 A1 - Amer Ali, A1 - Sykes Jonathan, A1 - Moore Christopher, PY - 2004 KW - null VL - 0 JA - 2010 14th International Conference Information Visualisation ER - | |||
Digital transducers, notably amorphous Silicon panels, are being used in image guided radiotherapy. Using kilo-voltage X-ray sources panel transducers are providing cone beam volume reconstruction. Theoretical considerations show that even sub-degree skew can result in the wandering of projection points across many detector elements to produce serious blurring of the cone beam reconstruction away from the imaging isocentre. The importance of identifying and correcting transducer skew is highlighted and shown to be of potentially greater importance than mechanical flex. Radiographic imaging of a suspended radio-opaque test object is described for direct characterisation of skew. The results of skew correction by image processing are presented. The use of 'auto-focusing' grey level change detection algorithms in cone beam reconstruction images, following programmed incremental angular transformation of the projection profiles of a 'Rando' anthropomorphic phantom, is shown to have the potential for automating skew correction.
Citation:
Amer Ali, Sykes Jonathan, Moore Christopher, "Imaging Panel Skew Correction and Auto-focusing in Radiotherapy Cone Beam Imaging," iv, pp.92-97, Eighth International Conference on Information Visualisation (IV'04), 2004
Usage of this product signifies your acceptance of the Terms of Use.