The Community for Technology Leaders
RSS Icon
Los Angeles, California USA
Mar. 31, 2009 to Apr. 2, 2009
ISBN: 978-0-7695-3507-4
pp: 156-161
In order to improve the time synchronization precision to insure the communication timely, several types of clock synchronization methods were compared, analyzed the IEEE1588 clock synchronization system, discussed the PTP system software programming, introduced some source code transplanting methods, got the root cause of the low precision, provided three major improving methods, tested the improved system, the results indicate the high precision time synchronization has been attained.
industrial Ethernet, clock synchronization, IEEE1588, one way delay, time offset
Qunli Shang, Rongjin Jiang, Shan-en Yu, "Analyze and Improve the Time Synchronization in EPA", CSIE, 2009, Computer Science and Information Engineering, World Congress on, Computer Science and Information Engineering, World Congress on 2009, pp. 156-161, doi:10.1109/CSIE.2009.671